Ordinary duty cords/flexibles are used where the risk of mechanical damage and mechanical stresses is normal, i.e. when cables are subject to low mechanical stresses in the areas of application, and the risk of mechanical damage is low, as is the case to be expected in the normal use of small to medium size equipment in domestic and commercial as well as in light industrial premises.
Examples of appliances that need ordinary duty cables include vacuum cleaners, toasters, washing machines, refridgerators, dryers and televisions.

Specification

Conductor

  • Plain Annealed Copper Class 5 Flexible to BS EN 60228

Insulation

  • PVC Type TI2 to BS EN 50363-3

Sheath

  • PVC Type TM2 to BS EN 50363-4-1

Min Operating Temperature

  • -15°C

Max Operating Temperature

  • 70°C

Min Bending Radius

  • 6 x ∅

Core Colours

  • 5 Core - Green/Yellow, Blue, Brown, Black, Grey
  • 4 Core - Green/Yellow, Blue, Brown, Black
  • 3 Core - Green/Yellow, Blue and Brown
  • Twin - Blue and Brown

Sheath Colours

  • White or Black, other colours available by special request

Current Carrying Capacity

  • For current ratings refer to table 4F3 of BS7671 IET Wiring Regulations
  • DPD Next Day service is based on business days, our cutoff for sending orders out is 14:00 Monday to Friday.
  • Orders received after this time will be despatched on the next working day.
  • If your delivery is of an urgent nature, please contact our Sales Team on 0121 502 5133 to confirm stock availability. As with all suppliers, we occasionally run out of stock of an item.
  • If any stock issues arise email notifications are sent out to confirm any delays to your order
  • Prices quoted are based on orders being placed on our website. If you require further information or assistance please call our Sales Team on 0121 502 5133.
  • If you include your email address and mobile number when you're placing an order you will get interactive updates from DPD



Send us a message

Recommended Products